DECT NR+ is finding its place on the factory floor

/

By



DECT NR+ is finding its place on the factory floor 

From Today to what’s next >>

I recently came across a DECT Forum webinar on the role of DECT NR+ in industrial applications that I found particularly interesting. The conversation brought together Roel Ottink from the DECT Forum, Fredi della Torre from Stratum 9, Matthias Bohge from R3 Solutions and Olivier Coutelou from Schneider Electric.

The original webinar can be found here: [WEBINAR LINK]

Rather than repeat the presentation, I wanted to share some of the things that stood out to me and why I think they matter.

Moving the discussion onto the factory floor

What I found particularly interesting was how quickly the discussion moved beyond the radio technology itself. Much of the webinar was spent looking at actual factory problems and considering what happens when wireless becomes part of the machinery and automation system rather than simply providing connectivity around it.

That changes the requirements considerably. Connecting a sensor that reports a temperature every few minutes is one thing. Controlling moving machinery over a wireless connection is quite another. In the latter case, knowing when the data will arrive can be more important than achieving the highest possible data rate.

This idea of predictability ran throughout the webinar and is one of the areas where DECT NR+ becomes particularly interesting for industrial applications.

Many familiar wireless technologies operate in shared spectrum where independent systems have to compete for access. This approach works extremely well for a huge range of applications, but it can make communication timing less predictable as the environment becomes busier. An occasional delay may be insignificant on an office network, but considerably more important when the wireless link forms part of a machine control system.

DECT NR+ can use scheduled access instead. Devices can be assigned transmission opportunities, allowing the network to coordinate when they communicate rather than leaving them continually competing for the channel. The important question for the industrial designer therefore becomes less about headline speed and more about whether data can be delivered within a known and repeatable timeframe.

Replacing a moving cable

Stratum 9 provided a good example with an electric monorail system of the type commonly used in automotive manufacturing. Carriers move continuously through the factory while exchanging control commands, position information, diagnostics and safety-related traffic with the automation system.

Their approach uses DECT NR+ to carry Ethernet traffic transparently at Layer 2 while giving priority to PROFINET and PROFIsafe traffic. This means the existing automation system does not have to be redesigned around the wireless network. From its perspective, the aim is for the radio connection to behave much like the cable it replaces.

That becomes more challenging when the carrier moves through the factory and passes between different radio cells. Communication has to continue during the handover without disrupting the control system. It is a good example of why industrial wireless cannot be judged simply by range, bandwidth or a best-case latency figure. The behavior of the connection while the machine is actually operating matters just as much.

Fredi summarized the objective rather neatly during the webinar: on the rail, NR+ should behave “like a cable, just without the cable.”

When two robots have to move as one

R3 Solutions approached the problem from a different direction, using autonomous mobile robots (AMRs) as the example.

The application involved two AMRs transporting an aircraft wing together. Rather than behaving as two independent vehicles, their movements have to remain synchronized so that they effectively operate as one machine. R3 described this as creating a virtual axis between the vehicles.

This is a very different requirement from simply connecting an AMR to the factory Wi-Fi network. The two vehicles need to exchange control information directly and predictably, and routing that communication through the wider factory infrastructure adds something that the application does not necessarily need.

DECT NR+ supports device-to-device communication, allowing this exchange to take place directly between the vehicles. R3 discussed cyclic communication below 10 milliseconds and support for established industrial protocols including PROFINET and EtherNet/IP.

The latency figure is interesting, but I think the architecture is more significant. A factory contains many different communication relationships. Some devices need access to the wider network, while others primarily need to communicate with nearby equipment. A wireless technology that can accommodate those different relationships gives system designers more freedom in deciding how the automation system should be structured.

Making the production line itself more flexible

Schneider Electric then looked at a less obvious use for industrial wireless: making production equipment easier to move.

Manufacturers increasingly need to reconfigure production lines as products and processes change. In food and beverage production, for example, equipment may be repositioned as recipes or product variants change. If every machine depends on fixed Ethernet or fiber connections, changing the production line also means changing its physical network infrastructure.

Removing that dependency can have benefits beyond simply making the machine easier to move. Schneider pointed to environments where equipment and floors undergo regular high-pressure cleaning. Reducing cable trays and physical connections can simplify that process. Moving equipment such as overhead cranes presents another example, because eliminating network cables that continually flex and wear can reduce maintenance requirements.

The discussion became particularly interesting when Schneider showed how wireless could change the automation architecture itself.

In a conventional arrangement, a machine might have its PLC installed locally. The wireless connection is then used to communicate with higher-level systems, while the time-critical control remains inside the machine. Schneider also showed an architecture where the PLC is moved into a central micro data center and controls the machine remotely.

In that case, wireless is no longer simply connecting the machine to the factory network. It has become part of the control loop, which makes predictable latency and high availability much more important.

Olivier described DECT NR+ as a strong candidate for these applications, particularly in small and medium-sized industrial sites where investing in a private cellular network may not make economic sense. I think this is an interesting position for NR+. There is a sizeable space between conventional wireless connectivity and a full private cellular deployment where manufacturers still need an engineered and predictable network.

The 1.9 GHz difference

The operating environment is another part of that story. DECT NR+ is part of the ITU IMT-2020 family, but its deployment model is quite different from the public cellular networks normally associated with 5G.

A manufacturer can deploy and control its own DECT NR+ network without depending on a mobile operator or SIM-based service. In Europe, it also has access to the 1.9 GHz DECT band rather than competing with the many unrelated technologies operating in the familiar ISM bands.

This does not mean the spectrum is exclusively occupied by NR+. Other members of the DECT family use it too. The difference is that these systems operate within a common coexistence framework designed for that spectrum. When the objective is to build a network whose behavior can be engineered and predicted, that is an important distinction.

A growing ecosystem

Another part of the webinar naturally caught my attention. The speakers discussed the silicon now available for DECT NR+ and identified Nordic Semiconductor as the company that helped kick-start the current ecosystem, with Last Mile Semiconductor now bringing a second chipset to market.

I obviously have a particular interest in that development, but having multiple silicon providers is important beyond LMS. Industrial products can remain in production for many years, and manufacturers need confidence that the technology behind them is developing into a sustainable ecosystem rather than depending indefinitely on one implementation.

There were other signs of this maturation in the webinar. The DECT Forum is organizing its activities around specific markets including industrial automation, building automation, smart metering and professional audio, while certification work is also progressing. These developments are less visible than a radio demonstration, but they are part of what turns a specification into something manufacturers can confidently design into products.

The technology itself is also continuing to develop. The webinar discussed current implementations using 1.7 MHz channels and the additional 3.4 MHz bandwidth supported by the new LMS silicon. The DECT NR+ standard goes considerably further, providing scope for wider bandwidths, different subcarrier spacings and further improvements in latency and data rate as future implementations emerge.

It is important to distinguish between what the standard allows and what commercial devices support today. I actually think the industrial examples presented during the webinar make that distinction encouraging. These applications are not dependent on some future version of DECT NR+. Companies are already developing systems around capabilities that exist now, while the standard leaves room for future silicon to extend what those systems can do.

The questions are changing too

The Q&A provided another indication of how the conversation around NR+ is developing. Participants were asking about smart metering, power consumption, security certification, regional spectrum availability and comparisons with other wireless approaches.

Not every question had an immediate answer, which is perhaps to be expected from a technology and ecosystem that are still developing. What interested me was the nature of the questions themselves.

They are increasingly the questions people ask when considering a technology for a real product or deployment. What silicon can I buy? Where can I operate it? How much power will it consume? How will it be certified? How does it integrate with the industrial network I already have?

That is a different conversation from asking whether the radio works.still g

From wireless technology to part of the factory

My main takeaway from the webinar was not a particular latency figure or individual feature. It was that the discussion around DECT NR+ is becoming grounded in the practical problems of industrial automation.

Can a moving carrier maintain its control connection as it travels through a factory? Can two AMRs coordinate directly closely enough to behave as one machine? Can production equipment be moved without rebuilding the communications infrastructure around it? Can wireless become part of the control path while remaining predictable enough for the automation system?

These are much more meaningful tests of an industrial wireless technology than a list of radio specifications.

Ultimately, factory operators should not have to care about the elegance of the radio protocol underneath. They need machines to communicate reliably, production lines to keep running and equipment that is easier to install, move and maintain.

What I found encouraging about this DECT Forum discussion was that the conversation is increasingly happening at exactly that level.

DECT NR+ is starting to move beyond being an interesting wireless technology and toward becoming part of the factory itself.

ND00051